Datasheets, whitepapers, case studies, and engineering documentation for liquid cooling infrastructure.
Detailed technical specifications, performance data, and dimensional drawings.
RDHx-1000 through RDHx-5000 series specifications, performance curves, and installation guides.
Download PDF — 2.4 MBCDU-500, CDU-1000, CDU-2000, and CDU-3000 series technical data and control specifications.
Download PDF — 3.1 MBRack manifolds, overhead distribution, and underfloor manifold specifications and flow data.
Download PDF — 1.8 MBDripless QDC series pressure ratings, materials, and compatibility matrices.
Download PDF — 1.2 MBComplete rack-level liquid cooling solution specifications and integration guides.
Download PDF — 2.7 MBAdiabatic and dry cooler capacity tables, fan performance, and environmental ratings.
Download PDF — 1.9 MBSensor specifications, communication protocols, and dashboard configuration guides.
Download PDF — 1.5 MBCable and point sensor specifications, alarm thresholds, and integration documentation.
Download PDF — 1.1 MBIn-depth analysis from our engineering team on liquid cooling technology and best practices.
Comprehensive analysis of thermal loads in GPU clusters, coolant selection, and infrastructure sizing for 100kW+ rack densities.
Download Whitepaper — 4.2 MBCFD analysis methodology, thermal resistance calculations, and real-world deployment performance data across multiple facilities.
Download Whitepaper — 3.8 MBAnalysis of propylene glycol, dielectric fluids, and corrosion inhibitors for long-term system reliability in data center environments.
Download Whitepaper — 2.9 MBEconomic analysis including CAPEX, OPEX, energy savings, and facility cost reductions over a 10-year operational lifecycle.
Download Whitepaper — 3.5 MBReal-world deployments demonstrating performance, efficiency, and reliability.
How Apex delivered 500MW of liquid cooling infrastructure for a leading AI research organization's training cluster, including 2,500 CDUs and 50,000 RDHx units.
Download Case Study — 2.1 MBDeploying direct-to-chip liquid cooling for a major investment bank's risk analytics platform, achieving PUE 1.08 and 40% energy reduction.
Download Case Study — 1.7 MBRetrofitting an existing 12MW colocation facility with RDHx and CDU infrastructure, enabling 50kW/rack density without building expansion.
Download Case Study — 1.9 MBDesign and installation of a custom direct-to-chip and RDHx hybrid system for a national university's 2.5 petaflop supercomputing cluster.
Download Case Study — 1.6 MBStep-by-step guides for design, installation, and operation.
Comprehensive checklist for data center architects and mechanical engineers designing liquid cooling infrastructure.
Download PDF — 0.8 MBDetailed procedures for CDU installation, pipe connections, system fill, leak testing, and operational handover.
Download PDF — 2.3 MBGuidelines for coolant quality monitoring, filtration, inhibitor replenishment, and system flushing schedules.
Download PDF — 1.4 MBPlanning considerations for retrofitting existing air-cooled data centers with rear door heat exchanger technology.
Download PDF — 1.6 MBRevit families, AutoCAD blocks, and 3D models for design integration.
BIM-compatible Revit families for all Apex products including parametric dimensions and connection points.
Download ZIP — 45 MBDWG format blocks for architectural and mechanical plan integration, including standard views and connection details.
Download ZIP — 18 MBSTEP AP214 format 3D models for mechanical design integration and interference checking.
Download ZIP — 62 MBOur applications engineering team can provide project-specific drawings, load calculations, and submittal packages tailored to your facility requirements.
Request Custom Documentation